leading supplier of cold chain solutions
FlashLink® Data Logger
      Model No. 20200 (REUSABLE)

Products

• Data Loggers
• Temperature Recorders
• Infrared Thermometers
• Probe Digital
   Thermometers

• Thermo-Hygrometers
• Thermo Labels/Kits/
   Ethylene Repair

• ISFET pH Meters

• Hot New Products
• Software Updates
• Ordering Info
• Press Releases
Search







FlashLink Data Logger with single internal temperature sensor for $39.00


Save yourself the time and hassle of manually recording the air temperature levels in your coolers or storage rooms by using the reusable FlashLink Data Logger. Reviewing the data is simple and easy. Record and archive the temperature data of your perishable products as they are shipped on your internal fleets from the DC to the retail facility, to gain additional control of temperature information and logistics issues during distribution.

The FlashLink Data Logger is a re-usable, credit card sized electronic temperature / humidity logger. All FlashLink Data Loggers are housed in a shock-resistant, waterproof case to withstand rugged and wet environments. A green LED indicator flashes when the data logger is active, and a red LED indicator flashes when alarm conditions occur, alerting you to out of range conditions.

The FlashLink Program Manager software (software sold separately) is a very user friendly and feature-rich program. Programmable features include logging intervals from 3 seconds to 24 hours, high and low alarm settings, adjustable alarm delays, delayed start from 0 seconds to 256 days, and a manual start button. Recorded information includes date, time, temperature data. Data logger model 20200 has a memory capacity of 3,822 data points. FlashLink’s patented design downloads 3,800 data points within 5 seconds, without the need for interface cables, by plugging directly into your parallel port or into your serial port through an optional serial port adapter. The easy to use software shows the recorded data in numeric or graph formats, with customizable fields, statistical data and alarm functions.


FlashLink Program Manager Software
FlashLink Data Logger
Model No. 20200


* Download Specifications (PDF)
20200

Need help purchasing?
Are you an existing customer?
    Yes     No
Name:
E-mail:
Phone:
Organization:
Product:
QTY:

Data Logger Specifications
Internal Temp Sensor Range
-40°F to 150°F (-40°C to 66°C)
Temperature Accuracy
±1°F (0.5°C) within -32°F to 150°F (0°C to 66°C)
±2°F (±1°C) otherwise
Temperature Resolution
0.1°F/C
Logged Data Capacity
3,822 data points
Data Download Time
5 second typical for 3,800 data points
Programmable Alarm Levels
High and Low Levels over entire range
Startup Alarm Delay
Skip 1 to 16 points
Operating Alarm Delay
0 to 79 minute delay filter
Logging Time Interval Range
3 seconds to 24 hours
Programmable Delayed Start
0 seconds to 256 days
LED Indicators
12-second flashing red for alarm; green for active
Battery Type
CR2450 3v lithium; user replaceable; 1-year life
Dimensions/ Enclosure
ABS plastic case, 3.25 x 2.25 x .75 in.
(8.3 x 5.7 x1.9 cm.)
Water Resistance
IP56
Shock Resistance
Withstands3-foot drop to hard surface
Certification Min. System Requirements
T.U.V.- CE Mark
IBM compatible 486 with 4MB RAM, WIN3.1, 95, 98, 2000, or NT
Software Requirements
FlashLink Program Manager Software Package Model 20222 or 20223