Save yourself the time and hassle of manually
recording the air temperature levels in your coolers or storage rooms by using the reusable FlashLink Data Logger.
Reviewing the data is simple and easy. Record and archive the temperature
data of your perishable products as they are shipped on your internal fleets
from the DC to the retail facility, to gain additional control of temperature information and
logistics issues during distribution.
The FlashLink Data Logger is a re-usable, credit card sized electronic temperature / humidity logger.
All FlashLink Data Loggers are housed in a shock-resistant, waterproof
case to withstand rugged and wet environments. A green LED indicator flashes
when the data logger is active, and a red LED indicator flashes when alarm conditions occur,
alerting you to out of range conditions.
The FlashLink Program Manager software (software sold separately)
is a very user friendly and feature-rich program. Programmable features include logging intervals from 3 seconds
to 24 hours, high and low alarm settings, adjustable alarm delays, delayed start
from 0 seconds to 256 days, and a manual start button. Recorded information includes
date, time, temperature data. Data logger model 20200 has a memory capacity of 3,822
data points. FlashLink’s patented design downloads 3,800
data points within 5 seconds, without the need for interface cables, by plugging directly
into your parallel port or into your serial port through an optional serial port adapter.
The easy to use software shows the recorded data in numeric or
graph formats, with customizable fields, statistical data and alarm functions.
FlashLink Program Manager Software
|
|
Data Logger Specifications |
Internal Temp Sensor Range |
-40°F to 150°F (-40°C to 66°C) |
Temperature Accuracy |
±1°F (0.5°C) within -32°F to 150°F (0°C to 66°C)
±2°F (±1°C) otherwise |
Temperature Resolution |
0.1°F/C |
Logged Data Capacity |
3,822 data points
|
Data Download Time |
5 second typical for 3,800 data points |
Programmable Alarm Levels |
High and Low Levels over entire range |
Startup Alarm Delay |
Skip 1 to 16 points |
Operating Alarm Delay |
0 to 79 minute delay filter |
Logging Time Interval Range |
3 seconds to 24 hours |
Programmable Delayed Start |
0 seconds to 256 days |
LED Indicators |
12-second flashing red for alarm; green for active |
Battery Type |
CR2450 3v lithium; user replaceable; 1-year life |
Dimensions/ Enclosure |
ABS plastic case, 3.25 x 2.25 x .75 in. (8.3 x 5.7 x1.9 cm.) |
Water Resistance |
IP56 |
Shock Resistance |
Withstands3-foot drop to hard surface |
Certification Min. System Requirements |
T.U.V.- CE Mark IBM compatible 486 with 4MB RAM, WIN3.1, 95, 98,
2000, or NT |
Software Requirements |
FlashLink Program Manager Software Package Model 20222 or 20223 |
|