FlashLink® Certified Vaccine USB PDF Data Logger, Model 40527

The FlashLink® Certified Vaccine USB PDF Data Logger is designed for monitoring temperature conditions inside storage units where vaccines and other temperature sensitive liquid medicines are kept. This reusable logger features a large, easy-to-read LCD and an external probe sealed in a 5ml glycol bottle. The glycol prevents false alarms by buffering the probe against sudden and expected temperature fluctuations during normal use, such as frequent door openings and cycling of the refrigerator or freezer. The glycol also emulates temperature changes experienced by most common fluids in storage, to give more accurate readings. The logger attaches to the outside of the storage door, while the sensor bottle is placed inside, allowing users to read current and minimum/maximum temperatures without opening the unit. A red LED alarm and low battery indicator are also visible on the display. This logger is compatible with CDC and WHO guidelines. Certificates are available for ISO 17025 and NIST calibration.

40527 FlashLink Certified Vaccine USB PDF Data Logger
 

The FlashLink Certified Vaccine USB PDF Data Logger provides an accurate reading, programmable alarms and sampling intervals, and a USB connection to quickly and easily download temperature data. The FlashLink Certified Vaccine USB PDF Data Logger can be programmed to start automatically or with the option for a delayed start allowing the glycol bottle sufficient time to stabilize to the refrigerator or freezer temperature.

  • Compatible with CDC guidelines
  • 21 CFR Part 11 compliant
  • Single channel, external sensor in glycol bottle
  • Automatically generates PDF report and CSV file
  • Glycol buffered sensor emulates products and prevents false alarms
  • Ideal for monitoring vaccines and liquid during storage
  • Audible and/or visual alarms
  • Low battery indicator on LCD
  • Quick disconnect cable to download logger
  • User programmable: manual or auto start, logging intervals, hi/low alarms
  • Scroll through recorded data on LCD

FlashLink Certified Vaccine USB PDF Data Logger
FeatureSpecification
DeltaTrak manufactures products under an ISO 9001:2008 registered quality management system
*Polyethylene terephthalate copolymer / **Generally Recognized As Safe
Sensor Measurement Range -58ºF to 104ºF (-50ºC to 40ºC)
Operating Range -58ºF to 77ºF (-50ºC to 25ºC)
Temperature Resolution 0.1°F/°C
Accuracy within Normal Operating Range ±1.0°F from -58°F to 77°F
(±0.5°C from -50°C to 25°C)
Data Capacity 32,496 data points
Data Download Time 5 seconds typical for 3823 points
Multiple Alarm Levels High & low levels and extreme high and low levels displayed on LCD, with audible buzzer
Battery Two AAA lithium batteries, LCD % remaining power indicator
Dimensions/Body 1.575 in x 3.66 in x 0.94 in (40 mm x 93 mm x 24 mm)
Casing ABS plastic
External Sensor Thermistor in 5 ml PETG* Sterile Bottle - 21CFR compliance information available, 3 meter cable with quick disconnect
Glycol Buffer Propylene glycol (GRAS** classified)
Weight 3.2 oz. (90.7 grams)
Certification 2 year ISO 17025 calibration certificate, CE Mark, Manufacturer’s Certificate of Compliance, RoHS compliant. Reference standards traceable to International System of Units (SI) through NIST.
Display LCD, Red LED Alarm
Waterproof Rating IP64 (with silicone cap)
Storage conditions -4°F to 122°F (-20°C to 50°C) 0% to 95% RH w/o condensation
Shelf Life 2 years (battery life)
System Requirements Windows PC with current operating system, Adobe Reader
Programming Supplied preconfigured for either refrigerator or freezer. User programmable using included FlashPDF Program Manager software.
Download Requirements Direct USB connection to PC (No special software required to download logger.)
Download FlashLink Certified Vaccine USB PDF Data Logger Spec Sheet   FlashLink Certified Vaccine USB PDF Data Logger spec sheet

FlashPDF Program Manager

FlashPDF Program Manager software is a user-friendly program that allows customers to download FlashLink Reusable Data Loggers. The software is purchased from DeltaTrak and is available to download from the DeltaTrak website. The program provides customers with traceability documentation and comprehensive programming capabilities. With this software the customer can view the recorded data in numeric or graph formats, with customizable fields, statistical data and alarm functions.

To download FlashPDF Program Manager, Click on the link below, select your region, then click the link for "FlashPDF Program Manager". On submitting the form you’ll click on Download button to start the download. Refer to the help file in the software for data logger configuration programming.

Download FlashPDF Program Manager Software

FlashLink Certified Vaccine Data Logger with Glycol Bottle
FlashLink Certified Vaccine Data Logger Quick Start Guide
AIM Webinar FlashLink Certified Vaccine Data Logger
Let us help you
Email Us
Call 1-800-962-6776
P.O.Box 398
Pleasanton, CA 94566

OrderNow

BLE Logger

White Paper and Solution Briefs