enzh-CNfrdejaptes
Installation Guide
  1. Remove paper strip from adhesive on the back of suction cup
  2. Place probe with suction cup in T-Floor on left side of container, close to supply air and bulkhead
  3. Place cable in the T-Floor, all the way to the back doors. Hang excess cable and connector end over the edge of the door opening to avoid damage from forklifts and pallets
  4. Load pallets into container, per usual procedure
  5. Connect stereo jack to FlashLink RTL 3G-2T In-Transit Logger
  6. Activate logger
  7. Remove paper strip from adhesive on back of logger sleeve
  8. After loading connect sensor cable to logger. After activation attach logger to carton on last pallet next to the doors

* Supply Air

22367_20K1